Lotus Lift UPS

Generative loads compatibility with patented function to efficiently use reinjected energy

Generator compatibility with ramp up configurable in power and break delay with wide input frequency range.

Wrong Phase Sequence Rotation Proof, the UPS can always supply the load under inverter.

Touch screen colour LCD display for easy to use and quick operation (14 selectable languages).

UPS information, settings and log file easily downloadable on removable SD card from LCD.

Flexible High Power Charger, with two strings of internal batteries up to 40kVA.

Wide range of battery number per string from 32 to 40 LCD settable (26-40 for 10kVA).

Ready for Li-ion or other battery technology. Real Time Battery Detection – immediate alarm once battery disconnected. Smart Battery Discharge – For Battery Discharge Test without extra loads and connections. Dual input and internal manual bypass, 440mm wide fits into higher IP cabinets.

Cold start (standard up to 20kVA, optional up to 80kVA). Parallelable up to 6 units, in power or redundancy with separate or common battery LCD settable. Wide communication offer as a standard: two com slots, RS232, USB, programmable dry contacts. Strong overload capacity (up to 300% for 3 seconds) to guarantee selectivity in the downstream installation.

Options:  SNMP, RS485, Modbus board, Parallel kit. Internal battery trays for easily battery service. Internal isolation transformer (up to 40kVA). External Temp. sensor and battery cabinets. Remote Touch Panel suitable to monitor up to 64 units with 3 prog. build-in Output Dry Contacts.

LOTUS Lift UPS Delivering clean, stable and reliable power for critical three-phase loads,Lotus-LT  is the best choice for small datacenters. And with a simplified maintenance helps reducing the TCO of the installation. Perfect Regenerative Mode function.With Lotus-LT Lift UPS has Regenerative Mode and back feed protection for elevator systems.  Lift UPS protect your system and main.

Up to 95% efficiency in online mode Built-in high current battery charger (10kVA with up to 7A standard charger) 4 poles manual bypass and breakers.

LOTUS-LT lift series is the optimum choice when the available space is limited.Moreover, the included features meet the needs of the majority of IT installations with a very positive value-for-money.

FEATURES

  • Generative loads compatibility with patented function to efficiently use reinjected energy
  • Generator compatibility with ramp up configurable in power and time delay with wide input frequency range
  • Wrong Phase Sequence Rotation Proof, the UPS can always supply the load under inverter
  • Touch screen colour LCD display for quick and user-friendly operation (14 selectable languages)
  • UPS information, settings and log file easily downloadable on removable SD card from LCD
  • Flexible High Power Charger, with two strings of internal batteries up to 40kVA
  • Wide range of battery number per string from 32 to 40 LCD settable (26-40 for 10kVA)
  • Ready for Li-ion or other battery technology
  • Real Time Battery Detection – immediate alarm once battery disconnected
  • Smart Battery Discharge – For Battery Discharge Test without extra loads and connections
  • Dual input and internal manual bypass, 440mm wide fits into higher IP cabinets
  • Cold start (standard up to 20kVA, optional up to 80kVA)
  • Parallelable up to 6 units, in power or redundancy with Common or Separate battery LCD settable
  • Wide communication offer as a standard: two com slots, RS232, USB, programmable dry contacts
  • Strong overload capacity (up to 300% for 3 seconds) to guarantee selectivity in the downstream installation

OPTIONS

  • SNMP, RS485, Modbus board, Parallel kit
  • Internal battery trays for easily battery service
  • Internal isolation transformer (up to 40kVA)
  • External Temp. sensor and battery cabinets OPTIONS
  • Remote Touch Panel suitable to monitor up to 64 units with 3 prog. build-in Output Dry Contacts

Use this manual / generic battery calculator: calculate the estimated operating time or the battery backup time of any UPS using the load in Watt, device efficiency, number of batteries per strings, strings number and the voltage of t